HyPix-3000

    Compact Photon Counting X-ray Detector

    Rigaku’s HyPix-3000 is a next-generation two-dimensional semiconductor detector designed specifically to meet the needs of the home lab diffractionist. One of the HyPix-3000’s unique features is its large active area of approximately 3000 mm² with a small pixel size of 100 μm², resulting in a detector with high spatial resolution. In addition, the HyPix-3000 is a single photon counting X-ray detector with a high count rate of greater than 10⁶ cps/pixel, a fast readout speed and essentially no noise.

    HyPix-3000 Overview

    Unprecedented Flexibility

    Featuring a double-threshold (window) discriminator, the HyPix-3000 has three readout modes that can be selected based on the purpose of a measurement. “Differential” mode can be used to suppress fluorescence from elements in a sample or background derived from cosmic rays. “31-bit” mode is used for experiments in which a very wide dynamic range is needed. “Zero dead time” mode makes it possible to perform extremely fast data collection.

    Easy to Use; Easy to Maintain

    The HyPix-3000 was designed for optimal flexibility and minimal maintenance. For example, the compact angular enclosure was designed to allow excellent high angle accessibility. Compared to the design of other types of detectors, the HyPix-3000 is essentially maintenance free. Unlike other types of detectors, it does not require an external cooling device as required on CCD detectors, or gas exchange and anode wire washing as required on multi-wire detectors.

    HyPix-3000 Features

    Available with Rigaku's SmartLab diffractometer
    Ultrahigh dynamic range and high sensitivity
    Seamless switching from 2D-TDI (Time Delay and Integration) mode to 2D snapshot mode to 1D-TDI mode to 0D mode with a single detector
    XRF suppression by high- and low-energy discrimination
    High spatial resolution, direct-detection pixel array detector

    HyPix-3000 Videos

    HyPix-3000 Specifications

    Technique Powder X-ray diffraction
    Benefit Fast, sensitive photon counting detector
    Technology Hybrid Photon Counting (HPC) X-ray detector
    Attributes Air-cooled HPC detector
    Computer External PC, MS Windows® OS
    Dimensions 147 (W) x 93 (H) x 180 (D) (mm)
    Mass 2 kg approx. (core unit)
    Power requirements 1Ø, 100-240 V, 15 A

    HyPix-3000 Application Notes

    The following application notes are relevant to this product

    HyPix-3000 Resources

    Rigaku Journal articles

    adobe Applications of the two-dimensional detector HyPix-3000 in X-ray diffractometry Read the Article
    adobe Evaluation of crystalline polymer materials using a 2D-SAXS/WAXS system Read the Article
    adobeGI-XRD measurements of thin film samples using a 2D detector and 2D-SAXS/WAXS attachment Read the Article

    Contact Us

    Whether you're interested in getting a quote, want a demo, need technical support, or simply have a question, we're here to help.